NYC METAL PANELSFIVE BOROUGHS · FABRICATE · INSTALL (home) Call or text (929) 209-3122 Free estimate

Rainscreen facades · Five boroughs

Dry-joint and open-joint metal rainscreen systems

Drained, back-ventilated ACM and aluminum plate rainscreen assemblies installed over continuous insulation, thermally broken clips and air-water barriers.

Call or text (929) 209-3122

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: a dry-joint rainscreen reveal between metal panels

AI-generated illustration

AI-generated illustration: open-joint metal rainscreen panels showing crisp shadow reveals and ventilated cavity.

Short answer

Dry-joint and open-joint metal rainscreen systems shed bulk rain at the outer aluminum panel while a ventilated cavity behind the cladding drains incidental moisture and lets the wall dry. We build commercial rainscreen facades in New York City using ACM or plate panels over continuous insulation, girts and air-water barriers, following the project's engineered shop drawings and tested wall assembly.

Key facts

Service area
All five boroughs of New York City: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

How a drained and ventilated metal rainscreen works

Traditional face-sealed cladding relies on perimeter and joint silicone to block every drop of wind-driven rain at the outer skin. Over seasons of thermal expansion and ultraviolet exposure, stressed sealant joints can separate and trap water behind a barrier facade. A dry-joint or open-joint metal rainscreen solves that physics problem by splitting weather protection into two distinct planes.

The outer plane—formed from ACM panels or single-skin aluminum plate—deflects the bulk of rainfall, wind load and sunlight while leaving open, spline-baffled or gasketed reveals without face sealant. Behind those panels sits a continuous ventilated air space, typically 1 to 2 inches clear. Any minor moisture that blows past an open reveal drops harmlessly down the back of the cavity and drains out through base and head weep flashings, while upward airflow equalizes air pressure and dries the interior wall.

Layers behind an open-joint or dry-joint facade

Every successful rainscreen elevation is built from the structural backup outward in a coordinated sequence:

  1. Continuous air and water barrier: Sheet-applied or fluid-applied membrane over exterior sheathing, concrete or masonry, flashed into every rough opening—scope our crew also performs under waterproofing.
  2. Continuous exterior insulation: Semi-rigid mineral wool or rigid insulation fastened tight against the barrier without blocking drainage channels.
  3. Thermally broken sub-framing: Fiberglass-reinforced or isolative spacer clips paired with extruded aluminum rails, Z-girts or hat channels that limit thermal bridging across the insulation layer.
  4. Hook-on or extruded panel cassettes: Shop-routed metal trays hung on concealed pins or extrusions so individual cassettes can expand thermally and be removed if damaged later.

Fire-retardant cores and NFPA 285 wall assemblies

On multi-story commercial and mixed-use buildings in New York City, building code rules on combustible exterior wall assemblies govern both core chemistry and cavity detailing. Where code and contract documents require an NFPA 285 tested wall assembly, design teams specify fire-retardant (FR) mineral-filled ACM cores, noncombustible A2-type composite cores or solid aluminum plate, paired with tested mineral wool insulation, air barriers and horizontal or perimeter fireblocking.

We do not engineer wall assemblies or issue compliance certifications. The project architect and engineer select the tested assembly and core type; our fabrication shop and installation crew build strictly to the approved shop drawings and the manufacturer's tested assembly details specified for the job.

Detailing windows, corners, parapets and transitions

Rainscreen performance wins or loses at panel edges. At storefront heads and window sills, metal closures and thru-wall flashings must direct cavity drainage outward without sealing shut required vent gaps. Perforated metal closures keep birds and insects out of bottom and top air intakes, while mitered or folded corner cassettes keep horizontal reveals aligned around building corners. At roof edges, plate parapet copings overlap the top of the ventilated cavity so water cannot enter behind the air barrier. Send your wall sections through our bid request page for pricing.

AI-generated illustration: close-up of an ACM panel edge: two thin aluminum skins and a solid core

AI-generated illustration

AI-generated illustration: cutaway edge of a composite facade panel showing two thin aluminum skins bonded to a solid core.

Rainscreen wall assembly questions

If rainscreen joints have no sealant, what stops water from entering the building?

In a dry-joint or open-joint rainscreen, the continuous air and water-resistive barrier applied directly over the exterior sheathing or masonry serves as the primary weather seal. The outer metal panels shed nearly all wind-driven rain, while any droplets passing an open reveal drain down the ventilated cavity and weep out.

Why are thermally broken clips used behind rainscreen metal panels?

Fastening continuous metal Z-girts straight through exterior insulation creates a continuous thermal bridge that conducts heat out of the building and lowers effective wall R-value. Thermally broken fiberglass or isolative-pad brackets space the rails off the backup wall so continuous mineral wool or rigid insulation performs as designed.

What is a pressure-equalized rainscreen panel system?

A pressure-equalized rainscreen divides the air space behind open or baffled panel joints into compartmentalized zones. When wind gusts hit the elevation, air enters the vents and quickly equalizes cavity pressure with exterior wind pressure, neutralizing the pressure drop that would otherwise pull rainwater inward through open reveals.

Can existing brick or EIFS commercial facades be re-clad with a metal rainscreen?

Yes, once the project's structural engineer confirms backup wall capacity and anchor pull-out loads. Existing masonry or stripped framed walls can receive air-and-water barrier upgrades, thermally broken wall brackets, continuous insulation and ventilated ACM or solid plate rainscreen cassettes that modernize the building and improve drainage.

How are insects and birds kept out of ventilated rainscreen cavities?

Perforated aluminum closure trims or corrugated vent strips are fastened along base weep intakes, window head breaks and top parapet exhaust gaps. Those closures maintain the free airflow cross-section needed for cavity ventilation and water drainage while preventing birds, wasps and windblown trash from entering behind the cladding.

Send rainscreen wall details for a quote

Attach architectural wall sections and elevations to price panels, sub-framing, insulation and barriers.

Rather text? Text photos to (929) 209-3122

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (929) 209-3122

    Call or text Monday–Friday, 7 AM–5 PM.

    Panels and barriers used in rainscreen walls

    Pricing an open-joint or dry-joint rainscreen?

    Book spring work now. Winter assessments and estimates available.