NYC METAL PANELSFIVE BOROUGHS · FABRICATE · INSTALL (home) Call or text (929) 209-3122 Free estimate

Field installation · Own crews & scaffold

Commercial metal panel installation in NYC

Our own insured crews hang ACM, plate and rainscreen wall panels across all five boroughs—installing panels from your fabricator or paired with our shop.

Call or text (929) 209-3122

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: a crew hanging metal wall panels from a pipe scaffold

AI-generated illustration

AI-generated illustration: crew on supported pipe scaffold installing commercial metal wall panels over an air-water barrier.

Short answer

Our own crews install commercial metal wall panels across the five boroughs, setting panels supplied by others or fabricated in our shop. We install air and water barriers, continuous insulation, sub-framing girts or thermally broken clips, and wet-seal or dry-joint panels from our own supported pipe scaffold or lifts. Send your architectural set and schedule for a written scope.

Key facts

Service area
All five boroughs of New York City: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

What goes on the wall before the first panel hangs

A flat, weather-tight metal wall panel elevation depends on the hidden backup layers installed weeks before finished cassettes arrive at the curb. When our crew mobilizes on a New York City commercial facade, we verify substrate conditions across exterior gypsum sheathing, concrete or CMU block and coordinate rough-opening tolerances with window and storefront installers.

Where our scope includes the backup envelope, we apply sheet or fluid-applied air and water-resistive barriers, detail self-adhered transition flashings at sills, jambs, heads and slab edges, and fasten continuous mineral wool or rigid insulation boards required by the energy code and wall section. Keeping barrier work and cladding under one crew eliminates finger-pointing over penetrations and fastener seals.

Sub-framing alignment, clips and reveal control

Buildings are rarely plumb to panel tolerances, especially on mid-rise overclads in Manhattan, Brooklyn or Queens. Our installers establish laser control lines for vertical and horizontal reveals, then fasten thermally broken structural clips, aluminum hat channels or galvanized Z-girts shimmed to bring the attachment plane true.

Depending on the engineered shop drawings, panels hang on hook-and-pin rainscreen rails, interlock into continuous perimeter extrusions, or fasten with color-matched rivets on secondary trims. In wet-seal route-and-return layouts, roughly 1/2-inch joints receive closed-cell backer rod and tooled low-modulus silicone sealant. In dry-joint rainscreen systems, open or baffled reveals are gauged evenly so shadow lines stay straight across window heads, storefronts and corners. Factory peel-off film stays on the PVDF finish until adjacent masonry, stucco or EIFS work is clear, then peels clean at turnover.

Supported scaffold access and trade coordination

Working over active sidewalks, courtyards and tight lot lines requires safe, predictable access. We own and erect supported pipe and frame scaffolding with our own crew, and we work from boom or scissor lifts where street frontage and site logistics suit mobile equipment. Owning our supported scaffold lets us match deck heights to panel module lines and adjust access without waiting on an outside scaffold vendor.

Installing panels furnished by others

Many general contractors, owners and national retail builders purchase ACM panels or solid aluminum plate panels directly from a fabricator and need an experienced, insured local installation subcontractor in the five boroughs. We regularly price installation-only packages: receiving sequenced crates at the curb, furnishing or setting the girt and clip sub-framing, hanging cassettes, closing parapet copings and completing perimeter sealant joints.

If you prefer single-source responsibility, we pair in-house shop fabrication with field installation under one contract. Our crews carry general liability, umbrella and workers' compensation insurance, and The Dom Construction Group LLC is registered on the New York State public work contractor registry. Submit your drawing set on our bid request page to get started.

Field installation sequence on the elevation

Coordinated field execution by our own crew from substrate check through protective film removal.

  1. Access setup and substrate layout

    We erect our own supported pipe scaffold or stage lifts, inspect sheathing or masonry, and snap laser lines for reveals and rough openings.

  2. Air-water barrier and continuous insulation

    Where included in our scope, we apply membranes, flash window perimeters and fasten mineral wool or rigid insulation boards.

  3. Thermally broken clips and sub-framing

    Wall brackets, Z-girts or hat channels and extrusion tracks are shimmed into a true, plumb plane verified before hanging begins.

  4. Hanging panels, copings and joint finishes

    Cassettes hang from bottom or control courses upward, wet-seal joints or open reveals are completed, parapet caps lock down the top and film peels clean.

Sub-framing, barrier layers and field hanging

AI-generated illustration: metal girts and clips over an air and water barrier, ready for panels

AI-generated illustration

AI-generated illustration: thermally broken clips, sub-framing girts and continuous insulation over exterior barrier.
AI-generated illustration: a wet-seal ACM joint with backer rod and silicone sealant

AI-generated illustration

AI-generated illustration: tooling silicone sealant over backer rod at a route-and-return panel reveal.
AI-generated illustration: finished metal panel facade on a city building

AI-generated illustration

AI-generated illustration: completed commercial metal wall panel elevation aligned with storefront glazing.

Field installation and site access questions

How do installers keep reveal lines straight over uneven backup walls?

Structural concrete, CMU block and framed walls frequently vary out of plumb across multi-story elevations. Before any track or cassette goes up, installers shoot horizontal and vertical laser benchmarks and shim thermally broken wall brackets, Z-girts or hat channels to establish a flat, true attachment plane across the facade.

When does the protective film come off newly installed panels?

Factory protective film stays on the panels during crating, hoisting, clip fastening and nearby wet-trade work so mortar, dust and sealant smears never touch the PVDF finish. Crews peel the film as each elevation zone wraps up so extended ultraviolet exposure cannot bake the film adhesive onto the coating.

How do your crews access multi-story elevations on tight NYC blocks?

The Dom Construction Group LLC owns supported pipe and frame scaffolding that our own crew erects to match floor lines and panel modules on tight five-borough sites. Where street frontage, courtyard geometry and site rules suit mobile equipment, our installers also work from boom lifts and scissor lifts.

What joint sealant is used on wet-seal metal panel systems?

Route-and-return wet-seal facades normally carry panel joints around 1/2 inch wide. Installers set oversized closed-cell polyethylene backer rod to control sealant depth and prevent three-sided adhesion, then tool non-staining, low-modulus architectural silicone formulated to adhere to fluoropolymer-coated aluminum returns while accommodating thermal expansion.

Get a field installation bid

Already buying panels direct? Send your drawings and panel system details for an install-only quote.

Rather text? Text photos to (929) 209-3122

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (929) 209-3122

    Call or text Monday–Friday, 7 AM–5 PM.

    Fabrication, scaffolding and backup trades

    Looking for an insured NYC panel installation crew?

    Book spring work now. Winter assessments and estimates available.