NYC METAL PANELSFIVE BOROUGHS · FABRICATE · INSTALL (home) Call or text (929) 209-3122 Free estimate

Commercial facades · All five boroughs

Commercial metal wall panels in New York City

ACM cassettes, solid aluminum plate cladding, soffits, canopies and rainscreen facades built from approved shop drawings for New York City commercial and mixed-use buildings.

Call or text (929) 209-3122

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: finished metal panel facade on a city building

AI-generated illustration

AI-generated illustration: commercial metal wall panel facade on a New York City mid-rise building.

Short answer

We fabricate and install commercial metal wall panels across all five New York City boroughs, including ACM cassettes, solid aluminum plate panels, soffits, canopies, column covers and copings. General contractors and owners can hire us for shop fabrication only, field installation only or a combined package built to the project's engineered shop drawings. Send PDF drawings or photos for free pricing.

Key facts

Service area
All five boroughs of New York City: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

Panel materials we fabricate and hang

Commercial facades in New York City rely on three main families of architectural metal cladding, each suited to different elevations and abuse levels. We work strictly on commercial and mixed-use building walls, soffits, canopies, fascia bands, column covers and parapet copings—never roofing, metal roofs or house siding.

  • Aluminum composite material (ACM panels, also called MCM): Two thin aluminum skins, each roughly 0.020 inch (0.5 mm) thick, bonded to a solid core at a standard 4 mm total thickness, with 3 mm and 6 mm sheets made for specialized profiles. Where building codes and contract documents call for an NFPA 285 tested wall assembly, architects specify fire-retardant (FR) mineral-filled or noncombustible A2-type cores; polyethylene (PE) cores are generally restricted to low-rise trim or sign bands where permitted.
  • Solid single-skin aluminum plate panels: Heavy-gauge 0.080-inch to 0.125-inch aluminum formed without a core, built for street-level storefronts, column wraps, canopies and heavy parapet caps where impact resistance and custom brake shapes matter most.
  • Formed metal wall panels: Factory-finished architectural wall profiles coated in durable PVDF fluoropolymer resins, FEVE, metallic and mica tones, anodized-look finishes or printed wood and stone patterns, delivered with peel-off protective film.

Wet-seal barrier joints versus drained rainscreens

Metal panel facades manage wind-driven rain in one of two ways, and the project's wall section dictates which system we build. In a route-and-return wet-seal system, panel edges are folded into 1-to-2-inch perimeter trays, hung on clips or extrusions, and sealed across roughly 1/2-inch reveals with closed-cell backer rod and silicone sealant. The panel face and sealant joint act together as the primary weather barrier.

In a dry-joint or open-joint rainscreen, face sealant is omitted. Open or spline-baffled reveals allow air movement into a ventilated cavity behind the panels, while an interior air and water-resistive barrier over the sheathing stops air leakage and drains any incidental moisture down to flashing weeps. Continuous mineral wool or rigid board insulation and thermally broken sub-framing clips typically sit inside that cavity.

Where commercial wall panels go on NYC buildings

Across the five boroughs, general contractors, developers and property managers bring us into mid-rise facade overclads, new commercial and multi-unit residential buildings, ground-floor retail storefronts, entrance canopies, deep exterior soffits, rooftop mechanical bulkheads and penthouse enclosures. Metal panels pair cleanly with curtain wall glazing, brick masonry, commercial EIFS and cement stucco, provided perimeter flashing and movement joints are detailed properly at every material change.

Three ways to buy our panel scope

Different general contractors buy facade packages differently, so we structure our work in three clear scopes:

  1. Shop fabrication only: You provide approved, engineered shop drawings; we CNC-route, fold, assemble extrusions and stiffeners, and ship labeled panel crates ready for your installers.
  2. Field installation only: You furnish panels from your supplier; our insured crews install backup barriers, girts, clips and panels from our own supported pipe scaffold or lifts.
  3. Fabricate and install: One subcontract covering shop trays, backup wall layers and field installation, priced from architectural PDFs via our bid request page.

Common facade problems that drive a panel re-clad

Property managers and general contractors usually call us onto existing NYC commercial buildings when older cladding shows one of these failures.

Split sealant and leaking panel reveals

Streaking, damp interior drywall or split rubber along wet-seal facade joints.

Usually means
Aged sealant adhered to dusty returns, missing backer rod or thermal movement exceeding joint width.
What we do
Cut out failed sealant and re-tool over proper backer rod, or overclad chronic barrier walls with a drained rainscreen assembly.

Oil-canning, dents and loose cassettes

Wavy panel faces, street-level impact dents or rattling trims along storefronts and sign bands.

Usually means
Undersized sheet thickness at sidewalk grade, missing rear stiffeners or corroded sub-framing clips.
What we do
Replace damaged runs with stiffened cassettes or upgrade street-level zones to heavy-gauge 0.080 to 0.125 inch solid aluminum plate.

Delaminated or chalked older facade panels

Peeling coatings, separated composite skins or mismatched patch panels across visible retail elevations.

Usually means
End-of-life non-fluoropolymer paint finishes or moisture trapped behind unventilated cladding.
What we do
Strip failed panels, inspect sheathing and air-water barriers, and install new PVDF-coated ACM or aluminum plate panels.

Failing parapet copings above the wall

Water staining below the roofline and wind-lifted sheet-metal caps.

Usually means
Thin coil-stock copings with open lap seams letting roof-edge water run behind the facade barrier.
What we do
Fabricate and install rigid brake-formed aluminum plate parapet copings locked over continuous cleats and splice plates.

Wall panel assemblies, joints and backup framing

AI-generated illustration: a wet-seal ACM joint with backer rod and silicone sealant

AI-generated illustration

AI-generated illustration: route-and-return wet-seal metal panel joint with backer rod and silicone sealant.
AI-generated illustration: a dry-joint rainscreen reveal between metal panels

AI-generated illustration

AI-generated illustration: dry-joint rainscreen metal wall panels with open reveals over a drained cavity.
AI-generated illustration: a metal panel soffit and canopy fascia over a storefront

AI-generated illustration

AI-generated illustration: commercial canopy fascia and metal soffit panels at a building entrance.

Metal wall panel system questions

When do New York City buildings require fire-retardant (FR) core ACM?

Where New York City building code provisions and project specifications require an NFPA 285 tested exterior wall assembly—common on multi-story commercial and mixed-use facades—the design team specifies fire-retardant (FR) mineral-filled or noncombustible A2-type cores. Standard polyethylene (PE) cores are generally limited to low-rise trim or sign bands where code allows.

What finishes are standard on commercial aluminum wall panels?

Factory coil-coated or spray-applied PVDF fluoropolymer coatings are the commercial facade standard because they resist chalking and color fade in urban sun and pollution. Panels are also manufactured in high-gloss FEVE coatings, metallic and mica shades, anodized-look finishes, brushed aluminum textures and printed wood-grain or stone patterns protected by peel-off film.

How thick are typical ACM wall panels compared with plate cladding?

Standard architectural ACM facade sheets are 4 mm thick overall, made from two 0.5 mm (roughly 0.020-inch) aluminum skins bonded to a central core, though 3 mm and 6 mm sheets also exist. Single-skin solid aluminum plate wall panels have no core and are ordinarily 0.080 inch, 0.090 inch or 0.125 inch thick.

Do you engineer or stamp shop drawings in-house?

No. We do not perform structural engineering, laboratory wall fire testing or professional engineering certification. Panel module sizes, clip spacing, girt gauges and core selections come from the project's engineered shop drawings, and our shop and field crews build strictly to those approved drawings and the specified tested assembly.

How do metal wall panels tie into adjacent glass, brick or EIFS?

Clean transitions depend on perimeter extrusions, metal jamb closures and stepped flashings detailed for differential thermal movement. In wet-seal walls, closed-cell backer rod and low-modulus silicone bridge the joint to storefront mullions, masonry or EIFS; in rainscreen walls, drained flashings and baffled reveals prevent trapped water at material changes.

Request metal wall panel pricing

Send architectural elevations, wall sections or facade photos. Let us know if you want fabrication, installation or both.

Rather text? Text photos to (929) 209-3122

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (929) 209-3122

    Call or text Monday–Friday, 7 AM–5 PM.

    Related panel and facade services

    Ready to review your elevation drawings?

    Book spring work now. Winter assessments and estimates available.