NYC METAL PANELSFIVE BOROUGHS · FABRICATE · INSTALL (home) Call or text (929) 209-3122 Free estimate

ACM / MCM panels · Five boroughs

Commercial ACM wall panels for New York City buildings

Flat, lightweight aluminum composite panels routed in our shop, hung by our field crew, or priced as a complete facade package from your approved drawings.

Call or text (929) 209-3122

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: close-up of an ACM panel edge: two thin aluminum skins and a solid core

AI-generated illustration

AI-generated illustration: aluminum composite panel showing two thin aluminum skins bonded to a solid core

Short answer

We fabricate, install, or furnish and install aluminum composite material (ACM) wall panels for commercial and mixed-use buildings across all five boroughs. Sheets are CNC-routed and folded into sharp-edged trays with fire-retardant or polyethylene cores as specified on the project drawings, then set as wet-seal or rainscreen systems. Send PDF drawings for pricing.

Key facts

Service area
All five boroughs of New York City: Manhattan, Brooklyn, Queens, the Bronx and Staten Island.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

How aluminum composite panels are built

Aluminum composite material—called ACM or MCM in US specifications—consists of two thin aluminum skins, each roughly 0.020 inches (0.5 mm) thick, permanently bonded to a solid core. A 4 mm overall sheet thickness is standard for commercial building facades, while 3 mm and 6 mm sheets are produced for sign bands, interior soffits, or specialized spans. Because the composite sandwich resists bending far better than bare sheet metal of the same weight, large modules up to about 60 inches wide stay flat on the wall without wavy faces or oil-canning.

Building-grade ACM arrives from the coil coater with a factory-applied fluoropolymer (PVDF) finish, or with FEVE, metallic, mica, anodized-look, brushed, or printed wood and stone finishes where the architect specifies them. Each sheet carries a peel-off protective film through CNC routing, return folding, delivery, and hanging, and the film stays on until surrounding trades finish adjacent work.

NYC Metal Panels builds commercial wall panels and facade cladding only—storefronts, mid-rise re-clads, new mixed-use elevations, canopies, soffits, column covers, and parapet copings. We do not install metal roofing, roof membranes, or residential house siding.

Core selection and NYC exterior wall assemblies

Not every ACM sheet carries the same core, and core type is critical on New York City buildings:

  • Fire-retardant (FR) mineral-filled core: Specified on multi-story commercial, institutional, and mixed-use buildings where the NYC Building Code and project drawings require an exterior wall assembly tested to NFPA 285.
  • Polyethylene (PE) core: Typically limited by code to low-rise storefront sign bands, canopies, and small accent areas where combustible cores are permitted.
  • Noncombustible / A2-type cores: Higher-mineral composite options selected by design teams for stricter fire-resistance criteria.

The project architect and engineer of record select the panel core, backup wall layers, and fireblocking details. We do not engineer, test, or certify wall assemblies ourselves; we fabricate and install strictly to the project's engineered shop drawings and the panel manufacturer's tested assembly requirements.

Wet-seal and drained rainscreen ACM systems

In the shop, sheets are cut on a CNC router with V- or U-grooves through the back skin and core, leaving the painted face skin intact so returns fold cleanly to a 1-to-2-inch tray depth. Corners are closed with aluminum angles, clips, or rivets, and stiffeners are bonded to the back of wider modules.

In the field, trays attach over exterior sheathing, an air and water barrier, continuous insulation, and aluminum or steel girts, hat channels, or thermally broken clips. Depending on the drawings, joints are finished either as a wet-seal barrier wall—roughly 1/2-inch reveals closed with backer rod and silicone sealant—or as a dry-joint rainscreen system with open or extruded reveals that drain and ventilate behind the panel face. At ground-floor service doors or heavy coping lines subject to cart and vehicle impacts, thicker single-skin plate panels often pair well with upper ACM bays.

Fabrication only, installation only, or full ACM scope

Serving the five boroughs from our Albany office, The Dom Construction Group LLC prices ACM packages three ways for general contractors, construction managers, developers, and commercial owners across Manhattan, Brooklyn, Queens, the Bronx, and Staten Island:

  • Complete furnish and install: Sheet ordering to spec, shop fabrication, delivery, sub-framing, and field installation by our insured crew.
  • Fabrication only: CNC-routed, folded, clipped, and labeled panels stacked for another installer.
  • Installation only: Field sub-framing and hanging of ACM panels supplied by others, worked from lifts or our own supported pipe scaffold.

Send your architectural drawings through our bid request page or call (929) 209-3122 for a free review.

Inside a routed ACM wall panel

AI-generated illustration: a routed ACM panel edge being folded up into a tray with square returns

AI-generated illustration

AI-generated illustration: routed ACM sheet folded into a return tray with protective film on the face
AI-generated illustration: a folded ACM panel corner with a riveted aluminum corner angle

AI-generated illustration

AI-generated illustration: closed ACM tray corner with perimeter extrusion and clip attachment

From approved ACM shop drawings to finished wall

How a commercial aluminum composite panel scope moves through shop fabrication and field installation.

  1. Drawing and spec review

    We verify sheet thickness, PE or FR core requirements, PVDF finish colors, joint type, and sub-framing details from your architectural and approved shop drawings.

  2. CNC routing and tray assembly

    Sheets are cut and V-grooved on a CNC router, folded into crisp return trays with protective film intact, fitted with corner clips, extrusions, and back stiffeners, and labeled by elevation.

  3. Barrier and sub-framing layout

    On furnish-and-install scopes, our crew checks the air and water barrier, installs thermally broken clips, Z-girts, or hat channels over continuous insulation, and sets laser control lines.

  4. Panel hanging, joints and film removal

    Trays are hung plumb with uniform reveal widths, wet-seal silicone or dry-joint trims are completed, and protective face film comes off once adjacent work is clear.

NYC ACM wall panel questions

When does an ACM facade in New York City require an FR core instead of a PE core?

Fire-retardant (FR) mineral-filled cores are used on multi-story and code-regulated buildings where the New York City Building Code and contract documents require an exterior wall assembly tested to NFPA 285. Polyethylene (PE) cores are combustible and are generally limited to low-rise storefront signs or small accent trims where permitted. The project architect and engineer of record determine the required core, insulation, and fireblocking details on the approved drawings.

What is the difference between ACM panels and solid aluminum plate panels?

ACM (aluminum composite material) bonds two thin aluminum skins, each around 0.020 inches thick, to a solid core, most commonly at a 4 mm total thickness. That sandwich stays very flat across wide modules while keeping weight low. Solid plate panels use a single thicker aluminum sheet, often 0.080 to 0.125 inches, giving higher dent resistance at street-level walls, column covers, and heavy parapet copings.

How does route-and-return shop fabrication keep folded ACM edges crisp?

During shop fabrication, a CNC router cuts a V- or U-shaped groove through the back aluminum skin and nearly all of the core while leaving the painted front skin untouched. Shop technicians then fold the perimeter along that groove to form a 1-to-2-inch return tray, securing the corners with internal angles, rivets, or clips and attaching perimeter extrusions to match the shop drawings.

When does the protective film come off new PVDF-coated composite panels?

Factory-coated ACM sheets ship with a directional peel-off film that protects the fluoropolymer (PVDF) finish during CNC routing, folding, crating, hoisting, and sub-framing installation. Installers fold the film back along panel return edges before setting wet-seal silicone or engaging dry-joint extrusions, then peel the face film off once overhead masonry, sealant, or glazing work is finished so mortar and tools never scratch the paint.

Do you engineer or NFPA 285 test ACM wall assemblies in-house?

No. Panel selection, wind-load calculations, thermal movement tolerances, and NFPA 285 wall assembly compliance remain the responsibility of the architect, engineer of record, and delegated shop-drawing engineer. Our shop and field crews fabricate and install strictly to the project's approved architectural drawings, engineered shop drawings, and the specified panel manufacturer's tested assembly details.

Send drawings for ACM panel pricing

Attach architectural PDFs or panel elevations and note whether you want fabrication only, installation only, or both.

Rather text? Text photos to (929) 209-3122

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (929) 209-3122

    Call or text Monday–Friday, 7 AM–5 PM.

    Related metal panel scopes

    Pricing an ACM facade or storefront band in NYC?

    Book spring work now. Winter assessments and estimates available.